{"product_id":"cold-group-on-overlapping-t-5-6","title":"Cold group on \"overlapping\" T° -5°+5°","description":"\u003cul\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003e\u003cspan lang=\"EN-GB\" style=\"mso-ansi-language: EN-GB;\"\u003eUnit width 400mm, small footprint.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003e\u003cspan lang=\"EN-GB\" style=\"mso-ansi-language: EN-GB;\"\u003eCooling capacity rendered 975 (W\/f) for chamber volume 6 m³\/6000L (internal T° 0°C and external T° +32°C).\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eRefrigerant expansion by capillary.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eOverlapping refrigeration units.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003e\u003cspan lang=\"EN-GB\" style=\"mso-ansi-language: EN-GB;\"\u003eClimatic class 5 certified (40°C temperature - 40% humidity).\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003e\u003cspan lang=\"EN-GB\" style=\"mso-ansi-language: EN-GB;\"\u003eAll units supplied as standard with high-pressure switch and KVL valve.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003e\u003cspan lang=\"EN-GB\" style=\"mso-ansi-language: EN-GB;\"\u003eAutomatic hot gas defrost with self-evaporation and overflow.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003e\u003cspan lang=\"EN-GB\" style=\"mso-ansi-language: EN-GB;\"\u003eThe evaporator drain is fitted with a resistor to prevent ice formation.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eR452a refrigerant gas.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003e\u003cspan lang=\"EN-GB\" style=\"mso-ansi-language: EN-GB;\"\u003eSupplied with cables and microswitch for door and light (light window supplied as standard).\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003e\u003cspan lang=\"EN-GB\" style=\"mso-ansi-language: EN-GB;\"\u003eMicroprocessor control with touch-sensitive keys.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp class=\"MsoNormal\"\u003e\u003cstrong\u003e\u003cu\u003e\u003cspan lang=\"EN-GB\" style=\"mso-ansi-language: EN-GB;\"\u003eINFO\u003c\/span\u003e\u003c\/u\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003cspan lang=\"EN-GB\" style=\"mso-ansi-language: EN-GB;\"\u003e:\u003cbr\u003eWarning:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan lang=\"EN-GB\" style=\"mso-ansi-language: EN-GB;\"\u003e as standard, the ideal ambient operating temperature must not be lower than 10°C. If this is not the case, then, a compressor preheating (A-PR-R), a pressure switch for the condenser fan (A-PVC-R) and a heated electrical panel (A-TEC-R) must be provided. In this case, the operating temperature cannot be lower than -5°C. Placed outdoors, the unit must be protected from weather elements.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cstrong\u003e\u003cu\u003ePLUS\u003c\/u\u003e:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0cm;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003e\u003cspan lang=\"EN-GB\" style=\"mso-ansi-language: EN-GB;\"\u003e400mm long units with small footprint, can be fitted to all our chambers (minimum 600mm panel).\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003e\u003cspan lang=\"EN-GB\" style=\"mso-ansi-language: EN-GB;\"\u003eAll units are supplied with a high-pressure switch as standard. Negative units are fitted with a thermostatic valve.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cb\u003eTechnical Specification\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003emm (W x D x H) : 400 x 320(796) x 714 - T° : -5°+5° - kW (elec) : 0.83\u003c\/li\u003e\n\u003cli\u003eCategory: Diamond\u003c\/li\u003e\n\u003cli\u003eRange: Refrigeration\u003c\/li\u003e\n\u003cli\u003eSubrange: Cold \u0026amp; freezing rooms\u003c\/li\u003e\n\u003cli\u003eFamily: Groupes to chevauchement\u003c\/li\u003e\n\u003cli\u003eSubfamily: T°-5° +5°\u003c\/li\u003e\n\u003cli\u003eLine: MONOBLOCK\u003c\/li\u003e\n\u003cli\u003eLength: 400 mm\u003c\/li\u003e\n\u003cli\u003eWidth: 320(796) mm\u003c\/li\u003e\n\u003cli\u003eHeight: 714 mm\u003c\/li\u003e\n\u003cli\u003eElectric Power: 0.83 kW\u003c\/li\u003e\n\u003cli\u003eWeight: 62 kg\u003c\/li\u003e\n\u003cli\u003eRestock Info: \/\u003c\/li\u003e\n\u003cli\u003eSupplier Delivery Delay: 42\u003c\/li\u003e\n\u003cli\u003eAvailability: 0\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Diamond","offers":[{"title":"Default Title","offer_id":53018138640651,"sku":"AP50M-1A","price":1841.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0756\/4486\/2731\/files\/001-AP-AN-M-big_bb38a7b0-c1dd-45eb-a7c5-119e5a5d8ae1.jpg?v=1775029321","url":"https:\/\/maxigastro.eu\/en-be\/products\/cold-group-on-overlapping-t-5-6","provider":"Maxigastro International","version":"1.0","type":"link"}